Features: •Portable, optional recorder •12.1"LCD, Six display interface •Monitor of ECG,HR,NIBP,SPO2,TEMP,RESP •720 hours trend data memory playback; 2 hours waveform memory playback; 1000 blood pressure data storage playback; 200 groups of alarm event memory •Network Specifications:ECGLead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)Lead selection: I, II, III, avR, avL, avF, V,Waveform: 2 chLead mode: 3 Leads ( R, L, F or RA, LA, LL)Lead selection: I, II, III,Waveform: 1 chGain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, autoHR and AlarmRangeAdult: 15 300 bpmNeo/Ped: 15 350 bpmAccuracy : ± 1% or ± 1bpm,which greatResolution: 1 bpmSensitivity: > 200 (uV P-P)Differential Input Impedance: > 5 MΩCMRRMonitor: > 105 dBOperation: > 105 dBDiagnosis: > 85 dBElectrode offset potential: ±300mVLeakage Current: < 10 uABaseline Recovery: < 3 S After Defi.ECG Signal Range: ±8 m V ( Vp-p )BandwidthSurgery: 1 15 HzMonitor: 0.5 35 HzDiagnostic: 0.05 100 HzCalibration Signal: 1 (mV p-p), Accuracy:±5%ST Segment Monitoring Range: Measure and Alarm -2.0 +2.0 mVARR DetectingType: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNCAlarm: AvailableReview: AvailableRESPARATIONMethod: Impedance between R-F(RA-LL)Differential Input Impedance: >2.5 MΩMeasuring Impedance Range: 0.3 5.0ΩBase line Impedance Range: 0 – 2.5 KΩBandwidth: 0.3 2.5 HzResp. RateMeasuring and Alarm RangeAdult: 0 120 rpmNeo/Ped: 0 150 rpmResolution: 1 rpmAccuracy : ±2 rpmApean Alarm: 10 40 SNIBPMethod: OscillometricMode: Manual, Auto, STATMeasuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)Measuring Period in STAT Mode: 5 MinPulse Rate Range: 40 240 bpmAlarm Type: SYS, DIA, MEANMeasuring and alarm range Adult ModeSYS: 40 270 mmHgDIA: 10 215 mmHgMEAN: 20 235 mmHg Pediatric ModeSYS: 40 200 mmHgDIA: 10 150 mmHg MEAN:20 165 mmHgNeonatal ModeSYS: 40 135 mmHgDIA:10 100 mmHgMEAN:20 110 mmHgResolution Pressure:1mmHgAccuracy Pressure Maximum Mean error: ±5mmHgMaximum Standard deviation: ±8mmHgOverpressure ProtectionAdult Mode: 297±3 mmHgPediatric Mode: 240±3 mmHgNeonatal Mode: 147±3 mmHgSpO2Measuring Range: 0 100 %Alarm Range: 0 100 %Resolution: 1 %Accuracy : 70% 100% ±2 % 0% 69% unspecifiedActualization interval: about 1 Sec.Alarm Delay: 10 Sec.Pulse RateMeasuring and Alarm Range: 20 300bpmResolution: 1bpmAccuracy : ±2bpmTEMPERATUREChannel: 1Measuring and Alarm Range: 0 50 °CResolution: 0.1°CAccuracy : ±0.1°CActualization interval: about 1 Sec.Average Time Constant:<10 Sec.